  1.         ╒═══════════════════════════════════════════╕
  2.         │                 xDISK                     │
  3.         │             Release 3.60.0                │
  4.         │                                           │
  5.         │ (C) Copyright 1989-1993 FM de Monasterio  │
  6.         │           All Rights Reserved             │
  7.         │            Licensed Material              │
  8.         ╘═══════════════════════════════════════════╛
  9.  
  10.                 ║ ║╔═╗╔═╣╔═╗╠═ ╔═╗
  11.                 ║ ║║ ║║ ║╔═╣║  ╠═╝
  12.                 ╚═╝╠═╝╚═╝╚═╝╚═╝╚═╝
  13.  
  14.    XDISK.SYS MESSAGES
  15.    ******************
  16.  
  17.    1.    "Abort - Program code has been corrupted"
  18.     -----------------------------------------
  19.    The program performs a full integrity test (32-bit Cyclical Redundancy
  20.    Check) prior to installation.  The message is displayed if a CRC error
  21.    is encountered, indicating corruption of the program code.
  22.  
  23.  
  24.    2.    "Abort - This program requires a ?86-CPU machine"
  25.     -------------------------------------------------
  26.    The 80x86 (Intel-compatible) CPU used by the machine is not compatible
  27.    with the CPU-type release of the xDISK version: the 286 release cannot
  28.    be used in 8088, 8086, and most 80186 CPUs, and the 386 release cannot
  29.    be used in 8088, 8086 80186, and 80286 CPUs.
  30.  
  31.  
  32.    3.    "Abort - Needs MS-DOS 3+ or a compatible DOS"
  33.     ---------------------------------------------
  34.    A DOS version fully compatible with MS-DOS 3.x (or later) is required
  35.    for proper program execution.
  36.  
  37.  
  38.    4.    "Abort - EMS manager not installed (INT 67h)"
  39.     ---------------------------------------------
  40.    The presence of a expanded memory manager (EMM), compatible with the
  41.    Lotus/Intel/Microsoft expanded memory specification (EMS) revision 4
  42.    or higher, could not be ascertained and the installation was failed.
  43.  
  44.  
  45.    5.    "Abort - Expanded memory error [EMS code ??h]"
  46.     ----------------------------------------------
  47.    The EMS manager encountered an error in allocating expanded memory for
  48.    the driver, in setting up the EMS page frame, or the EMS manager (EMM)
  49.    itself malfunctioned.  Several (hexadecimal) error codes are possible,
  50.    but those more likely to be found are listed below:
  51.  
  52.              80h: EMM internal error (manager corrupted)
  53.              81h: EMS hardware error
  54.              82h: EMM is busy
  55.              85h: Handles are exhausted
  56.              86h: Error in saving or restoring mapping context
  57.              87h: Requested more pages than physically available
  58.              88h: Requested more pages than currently available
  59.  
  60.  
  61.    6.    "Error - XMS manager not loaded/inactive"
  62.     "Install in conventional memory? [Yn]"
  63.     -----------------------------------------
  64.    The presence of an extended memory manager (XMM), compatible with the
  65.    Lotus/Intel/Microsoft/AST extended memory specification (XMS) version
  66.    2.x or later, could not be ascertained.  The user is given the option
  67.    to install xDISK in conventional memory or to abort the installation:
  68.    Press <Y> or <Enter> key to install, <N> or <Esc> key to cancel.
  69.  
  70.  
  71.    7.    "Unable to find UMB above requested limit"
  72.     ------------------------------------------
  73.    A free UMB was not available above the upper-memory limit specified via
  74.    switch /Hn; xDISK was installed at a lower UMB whose value is displayed
  75.    in the installation message.
  76.  
  77.  
  78.    8.    "Error - UMB allocation failed [XMS code ??h]"
  79.     "Install in conventional memory? [Yn]"
  80.     ----------------------------------------------
  81.    The XMM encountered an error during UMB allocation.  Press <Enter> or
  82.    <Y> key to install xDISK in conventional memory, and <Esc> or <N> key
  83.    to cancel the installation.  Several (hexadecimal) error codes may be
  84.    displayed:
  85.  
  86.              80h - Function is not implemented.
  87.              8Eh - General driver error occurred.
  88.              8Fh - Unrecoverable driver error occurred.
  89.              A9h - Parity error was detected
  90.              B0h - Smaller UMB is available.
  91.              B1h - No UMBs are available.
  92.              B2h - UMB segment number is invalid.
  93.  
  94.  
  95.    9.    "Error - UMB allocation failed [DOS code ??h]"
  96.     "Install in conventional memory? [Yn]"
  97.     ----------------------------------------------
  98.    MS-DOS 5+ encountered an error during UMB allocation.  Press <Enter> or
  99.    <Y> key to install xDISK in conventional memory and <Esc> or <N> key to
  100.    cancel the installation. Two (hexadecimal) error codes may be displayed:
  101.  
  102.              07h - Memory control blocks destroyed.
  103.              08h - Not enough free upper memory.
  104.  
  105.    If the error is due to the use of the DOS 5+ command DEVICEHIGH in *any*
  106.    line of CONFIG.SYS preceeding the command line installing XDISK.SYS (see
  107.    xDISK.DOC), the following message is also displayed in this message:
  108.  
  109.     "DEVICEHIGH command(s) in use - Cannot selfload into a UMB"
  110.  
  111.  
  112.    11.    "Error - Unable to restore UMA linkage [DOS code ??h]
  113.     -----------------------------------------------------
  114.    MS-DOS 5+ failed to restore its original link status to the upper memory
  115.    (linked/unlinked).  This not a fatal error, and in most cases the MS-DOS
  116.    booting will be completed. You should reboot again, however, to check if
  117.    the DOS error does not repeat; else press the <Esc> key before the xDISK
  118.    banner to avoid installing the device driver. (Please contact the vendor
  119.    if this message is displayed.)
  120.  
  121.  
  122.    12.    "**NON-RECOVERABLE DOS MEMORY ERROR [code ??h]**"
  123.     "Reboot machine. (Press the <Esc> key before the"
  124.     "xDISK banner if you want to avoid installation)"
  125.     -------------------------------------------------
  126.    During high memory selfloading under MS-DOS 5 control of UMB allocation,
  127.    DOS did not restore its block allocation strategy to the default setting
  128.    of 'first-fit low-memory only.' (Consequently, subsequent programs would
  129.    be allocated in upper memory only, and the operation of the system could
  130.    be compromised.)  xDISK halts the machine if the error were to occur, so
  131.    you can reboot the machine with a system diskette in drive A: and remove
  132.    the line in CONFIG.SYS installing XDISK.SYS.  (Please contact the vendor
  133.    if this message is displayed.)
  134.  
  135.  
  136.  
  137.    XDISK.EXE MESSAGES
  138.    ******************
  139.  
  140.    1.   "Not enough memory to preserve screen contents"
  141.         "Continue? [Yn] "
  142.     -----------------------------------------------
  143.    An additional 4400 bytes of memory, beyond the length of the program, are
  144.    required to save the screen contents (text mode only) if the Usage/Status
  145.    and Help panels are to be displayed.  This message is displayed when such
  146.    free memory is not available.  Press <Y> or <Enter> key to continue with-
  147.    out preserving screen contents, or <Esc> or <N> to cancel the display.
  148.  
  149.    If this message is displayed, the state of the mouse driver, if installed,
  150.    cannot be saved prior to the reset of this driver.  If this message is not
  151.    displayed, a maximum of 2 KB might be allocated (if available) to save the
  152.    driver state.
  153.  
  154.  
  155.    2.    "Invalid switch /Xx in command line"
  156.     ------------------------------------
  157.    Invalid switch character(s) /X(x) found during parsing of the DOS command
  158.    line; the program continues the parsing of command switches.
  159.  
  160.  
  161.    3.    "Invalid character entered in password string [X]"
  162.     "Use lower-case alphanumeric (a-z 0-9) characters"
  163.     --------------------------------------------------
  164.    An invalid character (i.e., neither a-z nor 0-9) was entered as part of
  165.    the requested password.  Execution is cancelled.
  166.  
  167.  
  168.    4.    "Drive X: is not an xDISK RAM-disk"
  169.     -----------------------------------
  170.    The selected drive unit <X:> is not a RAM disk created by xDISK.
  171.  
  172.  
  173.    5.    "X: is an invalid/unassigned drive [code xxh]"
  174.     ----------------------------------------------
  175.    The selected drive unit <X:> does not exist or DOS does not consider X:
  176.    a valid drive designator.
  177.  
  178.  
  179.    6.    "Abort - Program code is corrupted (CRC failure)"
  180.    7.    "Abort - This program requires a ?86-CPU machine"
  181.    8.    "Abort - This program requires MS-DOS 3 or later"
  182.    9.    "Abort - EMS manager not installed (INT 67h)"
  183.     -------------------------------------------------
  184.    See above.
  185.  
  186.  
  187.    10.   "Abort - Unknown video card/bad CRT controller"
  188.     ------------------------------------------------
  189.    The video adapter type could not be determined, or the video controller
  190.    chip was found to be incompatible.
  191.  
  192.  
  193.    11.    "Abort - EMS manager malfunction [code ??h]"
  194.     --------------------------------------------
  195.    The EMM encountered an error in (re)allocating or freeing an EMS block.
  196.    Several error codes are possible (see above).
  197.  
  198.  
  199.    12.   "Abort - Invalid address for EMS frame segment"
  200.     ------------------------------------------------
  201.    The xDISK driver for the requested unit returned an invalid address for
  202.    the EMS page frame.
  203.  
  204.  
  205.    13.   "Data in drive X: will be lost upon resizing ─ Continue? [yN]"
  206.     ---------------------------------------------------------------
  207.    Displayed (if switch /NQ or /ND is not specified in the DOS command line)
  208.    before any resizing operation that will destroy disk contents.
  209.  
  210.  
  211.    14.     "Adjusting ±nnn KB; data should be preserved - Continue? [yN]"
  212.     --------------------------------------------------------------
  213.    Displayed (if switch /NQ or /ND is not specified in the DOS command line)
  214.    in response to the selection of switch /DX±. The user is asked to confirm
  215.    the resizing (which should be able to preserve the contents of the disk).
  216.    Press <Y> or <Enter> to continue or <N> or <Esc> to cancel the resizing.
  217.  
  218.  
  219.    15.    "Disk formatting needed - Use switch /DB or /DE"
  220.     ------------------------------------------------
  221.    A collapsed disk needs to be uncollapsed with switch /DB[n][!] or /DE[!]
  222.    only.  See XDISK.DOC.
  223.  
  224.  
  225.    16.  "Drive X: is write protected - Use switch /TW-"
  226.     -----------------------------------------------
  227.    The status of the (selected disk) XDISK.SYS driver was previously set to
  228.    write protected (Read-Only) with switch /TW+; the status must be changed
  229.    with switch /TW- (Read/Write) before the disk can be resized.
  230.  
  231.  
  232.    17.  "Drive X: is resize protected - Use switch /TR-"
  233.     ------------------------------------------------
  234.    The status of the (selected disk) XDISK.SYS driver was previously set to
  235.    resize protected via switch /TR+; the status must be changed with switch
  236.    /TR- before the disk can be resized.
  237.  
  238.  
  239.    18.  "Warning - Switching to RAM-disk of fixed size"
  240.     -----------------------------------------------
  241.    The file system overhead sectors for an "elastic" disk formatting request
  242.    via switch /DB[n] are too large for proper functioning, so xDISK modified
  243.    the disk to an "inelastic" one. (Although neither switch /DB[n]! nor /DE!
  244.    was selected, switch /DX+ or /DX- requests will not be honored.)
  245.  
  246.  
  247.    19.  "Warning - The RAM-disk root directory is full"
  248.     -----------------------------------------------
  249.    All of the root directory entries of the RAM-disk are used, and new files
  250.    cannot be created in the root directory.  Either delete one root entry to
  251.    create a subdirectory to create new files (preserving the remainig files)
  252.    or resize with a larger /DRn value (destroying disk contents).
  253.  
  254.  
  255.    20.  "Warning - Drive contains nnn open file(s)..."
  256.     ----------------------------------------------
  257.    A data-destroying resize switch was selected and the disk contains <nnn>
  258.    open files that should be closed by DOS before resizing to preserve file
  259.    handles.
  260.  
  261.  
  262.    21.  "Abort - xDISK driver is corrupted or not loaded"
  263.     -------------------------------------------------
  264.    XDISK.EXE was unable to locate the resident XDISK.SYS driver code via the
  265.    communication interface of interrupt 2Fh, subfunction 0DDh (see XDISK.DOC
  266.    revision 3.40.00 or higher).
  267.  
  268.  
  269.    22.  "Abort - Wrong unit data returned by XDISK.SYS"
  270.     -----------------------------------------------
  271.    A sanity check of the xDISK communication interface (see above) failed to
  272.    yield the expected return, indicating memory corruption or malfunctioning
  273.    of the driver(s).
  274.  
  275.  
  276.    23.  "Error - Malfunction of xDISK driver [code ??h]"
  277.     ------------------------------------------------
  278.    The (selected disk) XDISK.SYS driver has passed back to XDISK.EXE an error
  279.    code indicating a driver malfunction.  The following hexadecimal codes may
  280.    be passed:
  281.  
  282.          Code 00h: Write-protect violation
  283.          Code 01h: Unknown unit
  284.          Code 02h: Drive Not Ready
  285.          Code 03h: Unknown Command
  286.          Code 08h: Sector Not Found
  287.  
  288.  
  289.    24.  "Abort - Unable to access XDISK.SYS [code ??h]"
  290.     -----------------------------------------------
  291.    Unless switch /DA+ has been selected, XDISK.EXE communicates with XDISK.
  292.    SYS via IOCTL (Input/Output Control) DOS function calls.  The message is
  293.    displayed if DOS encounters any error during the IOCTL call; a number of
  294.    hexadecimal error codes are possible.  The codes more likely to be found
  295.    are listed below:
  296.  
  297.          Code 01h: Invalid Function Code (a non-xDISK drive was selected)
  298.          Code 0Fh: Invalid Disk Drive (a non-existing drive was selected)
  299.          Code 05h: Access denied (drive corrupted)
  300.          Code 0Dh: Data invalid (drive corrupted)
  301.  
  302.  
  303.    25.  "Abort - Cannot shrink/expand DOS-unlinked disks"
  304.     -------------------------------------------------
  305.    A disk resizing request was specified for a unit that has been unlinked
  306.    from the DOS chain of drivers via switch /TL-.  Relink the driver first
  307.    via switch /TL+ and then reissue the resize request.
  308.  
  309.  
  310.    26.    "Abort - Disk resizing parameters out-of-range"
  311.     "Increase /DB or reduce /DR, /DS, or /CS value"
  312.     -----------------------------------------------
  313.    The EMS buffer size for the RAM-disk (specified with switch /DBn) is too
  314.    small to account for the sector size (/DSn), root directory size (/DRn),
  315.    and/or cluster size (/CSn).
  316.  
  317.  
  318.    27.    "Error - Temporary file access failed [code ??h]"
  319.     -------------------------------------------------
  320.    To implement some of the "elastic" disk features, xDISK makes use of DOS
  321.    services to create and then erase a temporary file in the root directory
  322.    of the RAM-disk.  If an error occurs when using these services, the free
  323.    space algorithm of switch /DX- will not be valid.
  324.  
  325.  
  326.    28.    "Error - Resizing of drive X: failed [code ??h]"
  327.     ------------------------------------------------
  328.    Requested resizing could not be accomplished.  The (selected disk) XDISK
  329.    .SYS driver passes a hexadecimal error code reflecting the nature of the
  330.    error.
  331.  
  332.  
  333.    29.    "Abort - DOS cannot access the RAM-disk"
  334.     ----------------------------------------
  335.    DOS is unable to access the disk to measure its free space.
  336.  
  337.  
  338.    30.    "Abort - Inelastic RAM-disks have a fixed size"
  339.     -----------------------------------------------
  340.    Switch /DX+ or /DX- (data-safe "elastic-disk" resizing) was requested for
  341.    a disk formatted by means of switch /DB[n]! or /DE! ("inelastic" disks).
  342.  
  343.  
  344.    31.    "Abort - Maximal expansion is already achieved"
  345.    32.    "Abort - Disk expansion may damage FAT entries"
  346.     -----------------------------------------------
  347.    Switch /DX+ was selected for an "elastic" RAM-disk whose size cannot be
  348.    expanded further if the integrity of disk contents is to be preserved.
  349.  
  350.  
  351.    33.    "Abort - Maximum shrinkage is already achieved"
  352.    34.    "Abort - Disk shrinkage may damage FAT entries"
  353.     -----------------------------------------------
  354.    Switch /DX- was selected for an "elastic" RAM-disk whose size cannot be
  355.    shrinked further if the integrity of disk contents is to be preserved.
  356.  
  357.  
  358.    35.    "Abort - Disk has less than 16 KB of free space"
  359.     ------------------------------------------------
  360.    Switch /DX- was requested for a RAM-disk having less than 16 KB of unused
  361.    space, so that shrinking would not free an EMS page (16 KB each).
  362.  
  363.  
  364.    36.    "Abort - Cannot shrink fragmented/unpacked disk"
  365.     ------------------------------------------------
  366.    Switch /DX- was selected for an "elastic" RAM-disk in which the free disk
  367.    space is not packed toward the end of the disk, i.e. there are free-space
  368.    gaps between used sectors.  Run first a disk packing utility, providing a
  369.    full compression of used sectors, and then reissue the xDISK command.
  370.  
  371.  
  372.    37.    "Error - Out-of-range shrinkage algorithm data"
  373.     ------------------------------------------------
  374.    A sanity check of the shrinkage algorithm of an "elastic" disk for which
  375.    switch /DX- was selected returned an invalid value.  Because data safety
  376.    cannot be insured, the shrinkage request is voided.
  377.  
  378.  
  379.  
  380.    Command-line Loading/Unloading Messages
  381.    ***************************************
  382.  
  383.    38.  "Loaded xDISK drive X:"
  384.         "Resident code length (decimal): nnn bytes"
  385.         "Loaded at (hexadecimal) address hhhh:0000"
  386.     -------------------------------------------
  387.    The specified driver was successfully loaded from the DOS command-line.
  388.    The messages provides information on the letter designator <d:> for the
  389.    new drive, the decimal length of the resident code, and the hexadecimal
  390.    memory address (offset 0000 of segment <hhhh>) where such code starts.
  391.  
  392.  
  393.    39.  "Error - Unrecognized or invalid DOS version"
  394.     ---------------------------------------------
  395.    A DOS version compatible with MS-DOS 3.x or 4.x is required for command
  396.    line loading or unloading of a xDISK device driver.  Neither service is
  397.    available under the DOS compatibility box of OS/2, MS-DOS or IBM PC-DOS
  398.    5.x, COMPAQ DOS 4.x or higher, and DR-DOS 5.x or higher.
  399.  
  400.  
  401.    40.  "Error - Failed to find the NUL driver"
  402.     ---------------------------------------
  403.    The program was unable to find the start of the DOS drivers chain.  This
  404.    may occur if DOS has been corrupted, or an incompatible operating system
  405.    system is being used.  You should reboot immediately if you receive this
  406.    message.
  407.  
  408.  
  409.    51.  "Error - Undocumented function 32h is not supported"
  410.     ----------------------------------------------------
  411.    This message indicates the the DOS version being used does not support a
  412.    necessary DOS undocumented function in question, and alternative methods
  413.    to obtain undocumented DOS data have failed or are not available.
  414.  
  415.  
  416.    52.  "Error - Critical failure upon accessing file"
  417.         "Check drive hardware and SHARE access rights"
  418.     ----------------------------------------------
  419.    This message is displayed whenever a DOS critical error (interrupt 24h)
  420.    is triggered by an attempt to open the driver file.  For diskette-based
  421.    operations, an empty diskette drive or opened drive bay can trigger the
  422.    error.  For nonremovable disk-based systems, a file-sharing error (i.e.
  423.    SHARE.EXE is loaded and the file has already been opened with a sharing
  424.    mode incompatible with read access request) can also trigger the error.
  425.  
  426.  
  427.    53.  "Abort - Specified file has zero length"
  428.    54.  "Abort - Specified file was not found"
  429.    55.  "Abort - Specified path was not found"
  430.    56.  "Abort - DOS denies access to the file"
  431.    57.  "Abort - Insufficient memory to load driver"
  432.    58.  "Abort - Specified file is too big to load"
  433.     --------------------------------------------
  434.    These messages are displayed when the corresponding error is triggered
  435.    when accessing the driver file.
  436.  
  437.  
  438.    59.  "Abort - Driver file is not an xDISK driver"
  439.     --------------------------------------------
  440.    This message indicates that the specified driver file does not contain
  441.    the proper data to identify it as XDISK.SYS.
  442.  
  443.  
  444.    60.  "Error - Loading of driver failed [code ??h]"
  445.     ---------------------------------------------
  446.    This generic error message is displayed when an error is encountered in
  447.    loading the driver file as an overlay.  The (hexadecimal) error code is
  448.    in the range between 01h and 58h, and is determined by DOS.
  449.  
  450.  
  451.    61.  "Error - Driver initialization failed [code ??h]"
  452.     -------------------------------------------------
  453.    This generic error message is displayed when an error is encountered in
  454.    the initialization of the driver by xDISK. The (hexadecimal) error code
  455.    is one of the following:
  456.  
  457.       Code   Error                             Code   Error
  458.        00    Write protect violation            08    Sector not found
  459.        01    Unknown unit                       09    Out of paper
  460.        02    Device not ready                   0A    Write fault
  461.        03    Unknown command                    0B    Read fault
  462.        04    CRC error                          0C    General failure
  463.        05    Bad request structure length       0D    Reserved
  464.        06    Seek error                         0E    Reserved
  465.        07    Unknown media                      0F    Invalid disk change
  466.  
  467.  
  468.    62.  "Abort - xDISK driver failed the installation"
  469.     ----------------------------------------------
  470.    This message is displayed when the initialization service of the device
  471.    driver fails the installation.
  472.  
  473.  
  474.    63.  "Error - Last available drive [X:] is assigned"
  475.         "and LASTDRIVE cannot be increased any further"
  476.     -----------------------------------------------
  477.    DOS assigns the first available drive letter to a disk within the default
  478.    range A: through E: or (for DOS 3.x or higher) the range A: through Z: if
  479.    the command 'LASTDRIVE=Z' has been given.  The message indicates that the
  480.    maximum range has already attained so that the xDISK device driver cannot
  481.    be loaded.  This also applies to Novell's NetWare drives.
  482.  
  483.  
  484.    64.  "Abort - Last available drive [X:] is assigned"
  485.         "LASTDRIVE has been increased to Y - Try again"
  486.     -----------------------------------------------
  487.    See above.  The program has increased the LASTDRIVE value to LASTDRIVE+1
  488.    (Y) so that the xDISK driver will be loaded if you repeat the execution.
  489.  
  490.  
  491.    65.    "Drive X: uninstalled"
  492.     ----------------------
  493.    The specified xDISK drive was successfully removed from memory.
  494.  
  495.  
  496.    66.    "Error - XMS manager (XMM) is not installed"
  497.     --------------------------------------------
  498.    The presence of an extended memory manager (XMM), compatible with the
  499.    Lotus/Intel/Microsoft/AST extended memory specification (XMS) version
  500.    2.x or later, could not be ascertained.
  501.  
  502.  
  503.    67.    "Error - Driver not loaded from the command line"
  504.     -------------------------------------------------
  505.    The request to uninstall an xDISK drive specified an xDISK RAM-disk not
  506.    loaded from the DOS command line.
  507.  
  508.  
  509.    68.    "Error - Device is not an xDISK driver"
  510.     ---------------------------------------
  511.    The request to uninstall an xDISK drive specified a non-xDISK drive.
  512.  
  513.  
  514.    69.    "Warning - Failed to find an xDISK gateway for drive X:"
  515.     --------------------------------------------------------
  516.    The request to uninstall an xDISK drive specified an xDISK RAM-disk not
  517.    installed from the command line or an invalid drive letter.  Retype the
  518.    request correctly or check the installed gateway names (i.e., XDISK_d:)
  519.    with a memory mapping utility.
  520.  
  521.  
  522.    70.    "Warning - Failed to release program environment [code ??h]"
  523.     ------------------------------------------------------------
  524.    The program was unable to release the DOS environment block of the driver
  525.    (lower memory loading) or its gateway (upper memory loading). The failure
  526.    is harmless to the operation of the program.
  527.  
  528.  
  529.    71.    "Warning - Failed to release lower memory block [code ??h]"
  530.     -----------------------------------------------------------
  531.    xDISK was unable to release the lower-memory block containing the driver
  532.    (LMB loading) or its DOS gateway to the upper memory (UMB loading). This
  533.    failure is harmless to the unlinking of the xDISK driver from the chain,
  534.    but the allocated memory block is unavailable to the conventional memory
  535.    pool for further use.
  536.  
  537.  
  538.    72.    "Warning - Failed to release allocated EMS block [code ??h]"
  539.     ------------------------------------------------------------
  540.    xDISK was unable to release the expanded memory block that was allocated
  541.    by the the driver during its initialization. This failure is harmless to
  542.    the unlinking of the driver from the DOS driver chain, but the allocated
  543.    block is unavailable to the EMS memory pool for further use.
  544.  
  545.  
  546.    73.    "Warning - Failed to release upper memory block [code ??h]"
  547.     -----------------------------------------------------------
  548.    xDISK was unable to release the upper-memory block containing the driver
  549.    (UMB load). This failure is harmless to the unlinking of the driver from
  550.    the driver chain, but the allocated block is unavailable to the XMS pool
  551.    for further use.
  552.  
  553.  
  554.    74.    "Warning - Failed to release memory control block [code ??h]"
  555.     -------------------------------------------------------------
  556.    In rebuilding the chain of memory, the program was not able to release a
  557.    memory control block allocated by a resident program installed after the
  558.    driver was loaded. The failure is harmless to the unlinking of the xDISK
  559.    driver from the driver chain, but the allocated memory is unavailable to
  560.    the memory pool for further use.
  561.  
  562.                 ----------------
  563.  
  564.          ┌─────────────────────────────────────────────────────────────┐
  565.          │ Trademarked names are the property of the respective owners │
  566.          └─────────────────────────────────────────────────────────────┘
  567.  [END]
  568.